BAS 3005S-02LRH E6327 数据手册
BAS3005S-02LRH
Low VF Schottky Diode
• Reverse voltage: 30 V
• Forward current: 0.5 A
• Low forward voltage and smallest package
form factor (1.0 x 0.6 x < 0.4 mm) for
mobile phone battery charger application
• Pb-free (RoHS compliant) package
BAS3005S-02LRH
1
2
Type
Package
Configuration
Marking
BAS3005S-02LRH
TSLP-2-17
single
5A
Maximum Ratings at TA = 25 °C, unless otherwise specified
Parameter
Symbol
Value
Unit
Diode reverse voltage1)
VR
30
V
Forward current1), TS ≤ 132 °C
IF
0.5
A
Non-repetitive peak surge forward current
IFSM
2
(t ≤ 10 ms)
150
Junction temperature
Tj
Operating temperature range
Top
-55 ...150
Storage temperature
Tstg
-65 ...150
°C
Thermal Resistance
Junction - soldering point2)
1
RthJS
≤ 60
K/W
For TA > 25 °C the derating of VR and IF has to be considered.
2For
calculation of RthJA please refer to Application Note Thermal Resistance
1
2011-06-20
BAS3005S-02LRH
Electrical Characteristics at TA = 25°C, unless otherwise specified
Parameter
Symbol
Values
min.
typ. max.
DC Characteristics
Reverse current1)
IR
µA
VR = 5 V
-
-
15
VR = 30 V
-
-
300
Forward voltage1)
mV
VF
IF = 0.1 mA
-
140
190
IF = 10 mA
-
260
310
IF = 200 mA
-
370
420
IF = 500 mA
-
450
500
-
10
15
AC Characteristics
Diode capacitance
CT
Unit
pF
VR = 5 V, f = 1 MHz
1Pulsed
test: tp = 300 µs; D = 0.01
2
2011-06-20
BAS3005S-02LRH
Diode capacitance CT = ƒ (VR)
Reverse current IR = ƒ (TA)
f = 1MHz
VR = Parameter
10 -2
35
A
pF
10 -3
IR
CT
25
20
10 -4
15
10
30 V
20 V
10 V
5V
10 -5
5
0
0
5
10
15
20
V
10 -6
0
30
25
50
75
°C
100
VR
150
TA
Reverse current IR = ƒ(VR )
Forward Voltage VF = ƒ (TA)
TA = Parameter
IF = Parameter
10A-2
0.5
V
10 -3
TA = + 125°C
10 -4
TA = + 85°C
500 mA
0.4
10
VF
IR
0.35
-5
TA = + 25°C
100 mA
0.3
10 -6
0.25
10 -7
0.2
10 mA
1 mA
0.15
10 -8
TA = - 40°C
0.1
10
-9
10 -10
0
0.05
5
10
15
20
V
0
-50
30
VR
-25
0
25
50
75
100
°C
150
TA
3
2011-06-20
BAS3005S-02LRH
Forward current IF = ƒ (VF)
Permissible Reverse voltage VR = ƒ (TA)
tp = Paramter, Duty cycle < 0.01
Device mounted on PCB with Rth = 160 K/W
10
A
0
35
V
VRmax
10 -1
IF
10 -2
10
20
125 °C
85 °C
25 °C
- 40 °C
-3
25
DC
20 ms
1 ms
15
10 -4
10
10 -5
5
10 -6
0
0.1
0.2
0.3
0.4
V
0
0
0.6
VF
20
40
60
80
100
°C
130
TA
Forward current IF = ƒ (TS )
BAS3005S-02LRH
600
mA
IF
400
300
200
100
0
0
15
30
45
60
75
90 105 120 °C
150
TS
4
2011-06-20
Package TSLP-2-17
BAS3005S-02LRH
Package Outline
Top view
Bottom view
0.39 +0.01
-0.03
0.6 ±0.05
0.05 MAX.
1
1
0.25 ±0.035 1)
2
1±0.05
0.65 ±0.05
2
0.5 ±0.035 1)
Cathode
marking
1) Dimension applies to plated terminal
Foot Print
0.45
Copper
Solder mask
0.375
0.35
0.275
1
0.925
0.3
0.35
0.6
0.275
For board assembly information please refer to Infineon website "Packages"
Stencil apertures
Marking Layout (Example)
BAR90-02LRH
Type code
Cathode marking
Laser marking
Standard Packing
Reel ø180 mm = 15.000 Pieces/Reel
Reel ø330 mm = 50.000 Pieces/Reel (optional)
0.5
Cathode
marking
8
1.16
4
0.76
5
2011-06-20
BAS3005S-02LRH
Edition 2009-11-16
Published by
Infineon Technologies AG
81726 Munich, Germany
2009 Infineon Technologies AG
All Rights Reserved.
Legal Disclaimer
The information given in this document shall in no event be regarded as a guarantee
of conditions or characteristics. With respect to any examples or hints given herein,
any typical values stated herein and/or any information regarding the application of
the device, Infineon Technologies hereby disclaims any and all warranties and
liabilities of any kind, including without limitation, warranties of non-infringement of
intellectual property rights of any third party.
Information
For further information on technology, delivery terms and conditions and prices,
please contact the nearest Infineon Technologies Office ().
Warnings
Due to technical requirements, components may contain dangerous substances.
For information on the types in question, please contact the nearest Infineon
Technologies Office.
Infineon Technologies components may be used in life-support devices or systems
only with the express written approval of Infineon Technologies, if a failure of such
components can reasonably be expected to cause the failure of that life-support
device or system or to affect the safety or effectiveness of that device or system.
Life support devices or systems are intended to be implanted in the human body or
to support and/or maintain and sustain and/or protect human life. If they fail, it is
reasonable to assume that the health of the user or other persons may be
endangered.
6
2011-06-20
BAS 3005S-02LRH E6327 价格&库存
很抱歉,暂时无法提供与“BAS 3005S-02LRH E6327”相匹配的价格&库存,您可以联系我们找货
免费人工找货